General
Manufacturer Cisco
Model Cisco WS-C2960+48TC-S
Manufacturer Part No WS-C2960+48TC-S

Cisco (WS-C2960+48TC-S) Catalyst 2960 Plus Switch


Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Lite

  • Fulfilled by Terrabyt
  •  Condition: New

Cisco (WS-C2960+48TC-S) Catalyst 2960 Plus Switch

Description
Configurations
10/100 Ethernet Interfaces
  • 24
Uplink Interfaces
  • 2 (SFP or 1000BASE-T)
Cisco IOS Software Feature Set
  • LAN Base
Available PoE Power
  • 370W (24 ports up to 15.4W)
Hardware
Flash memory
  • 64 MB
DRAM
  • 128 MB
Performance and Scalability
Forwarding bandwidth
  • 16 Gbps
Maximum active VLANs
  • 255
VLAN IDs available
  • 4K
Maximum transmission unit (MTU) - L3 packet
  • 9000 bytes
Jumbo frame - Ethernet frame
  • 9018 bytes
Forwarding Rate: 64-Byte L3 Packets, Millions of packets per second
  • 6.5
Mechanical
Dimensions (H x W x D)
  • 1.73 x 17.70 x 13.07 in (4.4 x 45.0 x 33.2 cm)
Weight
  • 12 lb (5.4 Kg)
Package Weight
  • 20.26 lb (9.19 Kg)
Environmental Ranges
Operating temperature up to 5000 ft (1500 m)
  • 23º to 113ºF
  • (-5º to 45ºC)
Operating temperature up to 10,000 ft (3000 m)
  • 23º to 104ºF
  • (-5º to 40ºC)
Short-term exception at sea level*
  • 23º to 131ºF
  • (-5º to 55ºC)
Short-term exception up to 5000 feet (1500 m)*
  • 23º to 122ºF
  • (-5º to 50ºC)
Short-term exception up to 10,000 feet (3000 m)*
  • 23º to 113ºF
  • (-5º to 45ºC)
Short-term exception up to 13,000 feet (4000 m)*
  • 23º to 104ºF
  • (-5º to 40ºC)
Storage temperature up to 15,000 feet (4573 m)
  • 23º to 158ºF
  • (-25º to 70ºC)
Operating altitude
  • Up to 10,000 Feet
  • (Up to 3,000 Meters)
Storage altitude
  • Up to 13,000 Feet
  • (Up to 4,000 Meters)
Operating relative humidity
  • 10% to 95% noncondensing
Storage relative humidity
  • 10% to 95% noncondensing
Sound Pressure, dBA
  • Typical, LpAm: 33
  • Maximum, LpAD: 36
Sound Power, dbA
  • Typical, LwA: 43
  • Maximum, LwAD: 46
MTBF in thousands of hours
  • 382
Connectors and Interfaces
Ethernet Interfaces
  • 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling
  • 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling
  • 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
  • 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
Indicator LEDs
  • Per-port status: Link integrity, disabled, activity, speed, and full duplex
  • System status, Port Status, PoE, RPS, link duplex, and link speed
Console
  • Cisco Catalyst console cables:
  • CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45
Power
  • The internal power supply is an auto-ranging unit and supports input voltages between 100 and 240V AC.
  • Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
  • The Cisco RPS connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.
  • Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle.
Management and Standards Support
Management
  • BRIDGE-MIB
  • CISCO-CABLE-DIAG-MIB
  • CISCO-CDP-MIB
  • CISCO-CLUSTER-MIB
  • CISCO-CONFIG-COPY-MIB
  • CISCO-CONFIG-MAN-MIB
  • CISCO-DHCP-SNOOPING-MIB
  • CISCO-ENTITY-VENDORTYPE-OID-MIB
  • CISCO-ENVMON-MIB
  • CISCO-ERR-DISABLE-MIB
  • CISCO-FLASH-MIB
  • CISCO-FTP-CLIENT-MIB
  • CISCO-IGMP-FILTER-MIB
  • CISCO-IMAGE-MIB
  • CISCO-IP-STAT-MIB
  • CISCO-LAG-MIB
  • CISCO-MAC-NOTIFICATION-MIB
  • CISCO-MEMORY-POOL-MIB
  • CISCO-PAGP-MIB
  • CISCO-PING-MIB
  • CISCO-POE-EXTENSIONS-MIB
  • CISCO-PORT-QOS-MIB
  • CISCO-PORT-SECURITY-MIB
  • CISCO-PORT-STORM-CONTROL-MIB
  • CISCO-PRODUCTS-MIB
  • CISCO-PROCESS-MIB
  • CISCO-RTTMON-MIB
  • CISCO-SMI-MIB
  • CISCO-STP-EXTENSIONS-MIB
  • CISCO-SYSLOG-MIB
  • CISCO-TC-MIB
  • CICSO-TCP-MIB
  • CISCO-UDLDP-MIB
  • CISCO-VLAN-IFTABLE
  • RELATIONSHIP-MIB
  • CISCO-VLAN-MEMBERSHIP-MIB
  • CISCO-VTP-MIB
  • ENTITY-MIB
  • ETHERLIKE-MIB
  • IEEE8021-PAE-MIB
  • IEEE8023-LAG-MIB
  • IF-MIB
  • INET-ADDRESS-MIB
  • OLD-CISCO-CHASSIS-MIB
  • OLD-CISCO-FLASH-MIB
  • OLD-CISCO-INTERFACES-MIB
  • OLD-CISCO-IP-MIB
  • OLD-CISCO-SYS-MIB
  • OLD-CISCO-TCP-MIB
  • OLD-CISCO-TS-MIB
  • RFC1213-MIB
  • RMON-MIB
  • RMON2-MIB
  • SNMP-FRAMEWORK-MIB
  • SNMP-MPD-MIB
  • SNMP-NOTIFICATION-MIB
  • SNMP-TARGET-MIB
  • SNMPv2-MIB
  • TCP-MIB
  • UDP-MIB
  • ePM MIB
Standards
  • IEEE 802.1D Spanning Tree Protocol
  • IEEE 802.1p CoS Prioritization
  • IEEE 802.1Q VLAN
  • IEEE 802.1s
  • IEEE 802.1w
  • IEEE 802.1X
  • IEEE 802.1ab (LLDP)
  • IEEE 802.3ad
  • IEEE 802.3af
  • IEEE 802.3ah (100BASE-X single/multimode fiber only)
  • IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports
  • IEEE 802.3 10BASE-T
  • IEEE 802.3u 100BASE-TX
  • IEEE 802.3ab 1000BASE-T
  • IEEE 802.3z 1000BASE-X
  • RMON I and II standards
  • SNMP v1, v2c, and v3
RFC compliance
  • RFC 768 - UDP
  • RFC 783 - TFTP
  • RFC 791 - IP
  • RFC 792 - ICMP
  • RFC 793 - TCP
  • RFC 826 - ARP
  • RFC 854 - Telnet
  • RFC 951 - Bootstrap Protocol (BOOTP)
  • RFC 959 - FTP
  • RFC 1112 - IP Multicast and IGMP
  • RFC 1157 - SNMP v1
  • RFC 1166 - IP Addresses
  • RFC 1256 - Internet Control Message Protocol (ICMP) Router Discovery
  • RFC 1305 - NTP
  • RFC 1492 - TACACS+
  • RFC 1493 - Bridge MIB
  • RFC 1542 - BOOTP extensions
  • RFC 1643 - Ethernet Interface MIB
  • RFC 1757 - RMON
  • RFC 1901 - SNMP v2C
  • RFC 1902-1907 - SNMP v2
  • RFC 1981 - Path MTU Discovery for IPv6
  • FRC 2068 - HTTP
  • RFC 2131 - DHCP
  • RFC 2138 - RADIUS
  • RFC 2233 - IF MIB v3
  • RFC 2373 - IPv6 Aggregatable Addrs
  • RFC 2460 - IPv6
  • RFC 2461 - IPv6 Neighbor Discovery
  • RFC 2462 - IPv6 Autoconfiguration
  • RFC 2463 - ICMP IPv6
  • RFC 2474 - Differentiated Services (DiffServ) Precedence
  • RFC 2597 - Assured Forwarding
  • RFC 2598 - Expedited Forwarding
  • RFC 2571 - SNMP Management
  • RFC 3046 - DHCP Relay Agent Information Option
  • RFC 3376 - IGMP v3
  • RFC 3580 - 802.1X RADIUS
Voltage and Power Ratings
  • Voltage (Autoranging)
  • 100 to 240 VAC
Current (Amperes)
  • 4.0 – 2.0
Frequency
  • 50 to 60Hz
Power Rating (kVA)
  • 0.43
DC Input Voltages (RPS Input)
  • 2A at 12V (7A at -52V)
Power Consumption
  • 0% traffic: 35.4
  • 10% traffic: 35.3
  • 100% traffic: 35.6
  • ATIS weighted average: 35.3
Safety and Compliance
Regulatory Compliance
  • Products should comply with CE Marking per directives 2004/108/EC and 2006/95/EC
Safety
  • UL 60950-1 Second Edition
  • CAN/CSA-C22.2 No. 60950-1 Second Edition
  • EN 60950-1 Second Edition
  • IEC 60950-1 Second Edition
  • AS/NZS 60950-1
  • EMC - Emissions
  • 47CFR Part 15 (CFR 47) Class A
  • AS/NZS CISPR22 Class A
  • CISPR22 Class A
  • EN55022 Class A
  • ICES003 Class A
  • VCCI Class A
  • EN61000-3-2
  • EN61000-3-3
  • KN22 Class A
  • CNS13438 Class 
EMC - Immunity
  • EN55024
  • CISPR24
  • EN300386
  • KN24




Tags: Cisco WS-C2960+48TC-S Price Dubai Cisco WS-C2960+48TC-S Supplier Dubai Cisco WS-C2960+48TC-S Sale Dubai Cisco WS-C2960+48TC-S Features Dubai Cisco IT Products Dubai Cisco IT Supplies Dubai Cisco IT Store Dubai Cisco Distributor Dubai Cisco Shop Dubai Cisco Store Dubai

show more
General
Manufacturer Cisco
Model Cisco WS-C2960+48TC-S
Manufacturer Part No WS-C2960+48TC-S

Write a review

Note: HTML is not translated!
    Bad           Good

Products You May Like

Anker Powerline II Lightning Cable (0.9m/3ft) – Black - A8432H12

Anker Powerline II Lightning Cable (0.9m/3ft) – Black - A8432H12

AED 47 USD 13


D-Link (DMC-805P) 10/100/1000Base-T Gigabit PoE Twisted-pair to SFP (Mini GBIC) Slot Gigabit PoE Media Converter

D-Link (DMC-805P) 10/100/1000Base-T Gigabit PoE Twisted-pair to SFP (Mini GBIC) Slot Gigabit PoE Media Converter

Oxion OX-GPS5248-2S Ai-PoE Switch 48GE PoE

Oxion OX-GPS5248-2S Ai-PoE Switch 48GE PoE

AED 2,083 USD 568


FortiGate (FG-200E-BDL-950-36) Hardware plus 3 Year

FortiGate (FG-200E-BDL-950-36) Hardware plus 3 Year

Tenda SM108 8-Port 2.5G Ethernet Switch

Tenda SM108 8-Port 2.5G Ethernet Switch

Avalon (AN-FS42U800X800) 42U x 800(W) x 800(D) - Rack with Perforated Back Door

Avalon (AN-FS42U800X800) 42U x 800(W) x 800(D) - Rack with Perforated Back Door

Promate BiPlug 2.4A Wall Charger with Dual USB Ports ,white

Promate BiPlug 2.4A Wall Charger with Dual USB Ports ,white

AED 37 USD 10


Anker A2566H11 Power Wave Select Plus Magnetic Pad

Anker A2566H11 Power Wave Select Plus Magnetic Pad

AED 82 USD 22


MikroTik  CRS125-24G-1S-IN Cloud Router Gigabit Switch

MikroTik CRS125-24G-1S-IN Cloud Router Gigabit Switch

Tenda A301 V2.0 Extender

Tenda A301 V2.0 Extender

AED 126 USD 34


Aruba 10G SFP+ LC SR 300m MMF XCVR

Aruba 10G SFP+ LC SR 300m MMF XCVR

3M Corning Cat6a Keystone Jack RJ45

3M Corning Cat6a Keystone Jack RJ45

Cisco WS-C2960+48TC-S price

Cisco (WS-C2960+48TC-S) Catalyst 2960 Plus Switch

Computer Shop

Track Your Order Here Whatsapp +97142380921
Call Now Button