General | |
Manufacturer | HP |
---|---|
Model | HPE ML110 |
Manufacturer Part No | P21439-421 |
EAN Code | 0190017408026 |
Compatible Country | Middle East, Africa, Iran, Dubai |
Country of Origin | California |
HPE P21439-421 ProLiant ML110 Gen 10 3206R 16GB 4LFF 550W Server Tower
- Brand: HP
- Model: HPE ML110
- Availability: Call For Price
- Part No: P21439-421
The HPE ProLiant ML110 Gen10 delivers a performance that meets the growing needs of the SMB. The server is a single processor, 4.5U Tower Server that is designed to provide enterprise class features such as redundancy, reliability, and manageability. The server delivers the right size Tower with performance and expandability that covers a wide range of applications and workloads and addresses our customers from SMB to enterprise class server ROBO environments. Accelerate your business with this right-sized computer.
System Unit
Tower Dimensions 17.32 (H)x 7.68.(W) x 18.92. (D) in (44 x 19.5 x 48.05 cm)
Input Requirements (per power supply)
Rated Line Voltage 100 to 120 VAC
Rated Input Frequency For 350W & 550W Power Supply:8A (at 100~240 VAC)
50 to 60 Hz
Rated Input Power For 550 W Power Supply:< 639 W (at 100 VAC),< 605 W (at 200 VAC)
For 350 W Power Supply:< 427 W (at 100 VAC),< 427 W (at 200 VAC)
BTU Rating
Maximum For 550 W Power Supply:2204 BTU/hr (at 100 VAC),2113 BTU/hr (at 200 VAC)
For 350 W Power Supply:1452 BTU/hr (at 100 VAC),1544 BTU/hr (at 200 VAC)
Power Supply Output (per power supply)
Rated Steady-State Power For 550 W Power Supply:550 W (at 100 VAC),550 W (at 200 VAC),
Maximum Peak Power For 350 W Power Supply:350 W (at 100 VAC),350 W (at 200VAC),
System Inlet Temperature
Standard Operating Temperature 10 to 35C (50 to 95F) at sea level with an altitude derating of 1.0C per every 305 m (1.8F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20C/hr(36F/hr). The upper limit and rate of change may be limited by the type and number of options installed. System performance during standard operating support may be reduced if operating with a fan fault or above 30C(86F).
Extended Ambient Operating Support For approved hardware configurations, the supported system inlet range is extended to be: 5 to 10C (41 to 50F) and 35 to 40C (95 to 104F) at sea level with an altitude derating of 1.0C per every 175 m (1.8F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048m (10,000 ft). The approved hardware configurations for this system are listed at System performance may be reduced if operating in the extended ambient operating range or with a fan fault.
Non-operating -30 to 60C (-22 to 140F). Maximum rate of change is 20C/
hr (36F/hr).
Relative Humidity (non-condensing)
Operating 8% to 90% - Relative humidity (Rh), 28C maximum wet bulb temperature, non-condensing.
Non-operating 5 to 95% relative humidity (Rh), 38.7C (101.7F) maximum wet bulb temperature, non-condensing.
Altitude
Operating 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
General | |
Manufacturer | HP |
---|---|
Model | HPE ML110 |
Manufacturer Part No | P21439-421 |
EAN Code | 0190017408026 |
Compatible Country | Middle East, Africa, Iran, Dubai |
Country of Origin | California |